Description
Frequency converter CFM110 – 0.25kW
Supply voltage:
Uin 1ph x 220 V (+10%, -15%)
Supply voltage frequency: 45 – 66 Hz
Output voltage: 3ph x 0 – Uin
Output frequency: 0; 1 - 800 Hz
Frequency generation error: 0.05 Hz
Type of PWM modulation: voltage vector
Motor connection:
Standard three-phase asynchronous motor 220/380V with triangle connection of windings «∆»
Control Mode:
- Scalar U/ƒ with linear (proportional) characteristic.
- Scalar U/ƒ with quadratic characteristic.
- Scalar U/ƒ with forced characteristic.
Control frequency of power module:
3 – 6 – 9 – 12 kHz
Rotation speed setting:
- Analog inputs
- Digital inputs
- Control Panel
- PID controller
- RS485 communication interface
Resolution ability:
0,1% for analog input and 0,1 Hz for the control panel and digital inputs
Braking modes:
- DC braking
Cooling:
Passive air cooling
2 analog inputs AN.IN1 и AN.IN2:
- in voltage mode: 0…10 V, Rin ≥ 50 kOhm
- in current mode: 0 (4)…20 mA, Rin = 220 Ohm
6 galvanically isolated digital inputs with switchable polarity:
NPN
- active level: 0 V
- inactive state:
20…24 V
PNP
- active level:
20…24 V
- inactive state: 0 V
Resistance:
Rin ≥ 4 kOhm.
1 analog output:
0…10V
1 digital output with open collector: up to 1A / 0...40V
Fully programmable signal source.
2 relay with changeover contacts:
commutation load: 250 V / 10A (AC)
Fully programmable signal source.
- Supports operation of the RS485 communication module with a galvanically isolated channel.
- Communication protocol Modbus RTU
- Supported baud rates: 4800, 9600,19200, 38400, 56000 or 115200 bps
- Possibility of individual and group changes of FC parameters by a top-level device.
- Implemented PC software with a flexible configuration management capabilities.
Meter counter:
- allows to use the FC in systems with conveyor and pulling mechanisms, when it is necessary to control the measured length or quantity of product in pieces.
Built-in PID controller:
- allows to launch a closed loop for stabilization of any technological parameter whose value can be measured.
Configuration management:
- user can save and load pre-configured personal configurations into the non-volatile memory of the FC. It is possible to quickly reset the FC to a factory settings.
- from current overloads of the FC
- from overvoltage on the DC bus
- from reducing the voltage on the bus during operation
- from starting the electric motor when there are only two phases
- from electric motor overload
- from electric motor underload (switchable)
- against loss of communication via RS485
- from overheating of the converter and/or electric motor
- from interphase short circuit
- from short circuit to ground of any phase
- from system failures and other functional errors
Узнать больше о серии CFM110.
Скачать полное руководство по эксплуатации.
Ознакомиться с сертификатами соответствия.
Часто задаваемые вопросы и ответы на них.
Посмотреть как настроить и выполнить ввод в эксплуатацию частотника.

3D Models